- KM 04:29 PM Support: RE: MityCam B2521 CAL / WCAL commands
- I think knowing that they are not applied in the uncorrected modes is sufficient. What about CDS? Are there any differences in how that functions between the modes? Basically I am attempting to get as RAW and uncorrected data as possible...
- MW 02:47 PM Support: MityCam B2521 CAL / WCAL commands
- Hi Kyle,
You can operate the sensor without calibration gain or offset data set
using the SGAN command.
<SGAN 3> is high gain only (no corrections)
<SGAN 4> is low gain only (no corrections)
<SGAN 5> is combined high / low gain (no cor... - Is it possible to remove/reset (set to zero) the calibration coefficients that are set by running the CAL and WCAL commands? Is there a way to figure out what they are set to?
Thanks,