- JM 07:53 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
- Anton,
The dark calibration would have been cleared when you reflashed the SD card. For best performance, you should set the clock to your desired rate, then run the calibration command with the sensor darkened. The calibration values... - AB 05:19 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
- Update. It return non zero images only for exposures bigger than 6 sec.
With exposures in interval 6.01 - 6.1 sec images are partially zero (lower part of image). More exposure - less zero valued part.
The same issue on 80MHz also. - AB 03:07 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
- Jeffrey,
Thank you for your reply. I've upgraded a firmware successfully. Now it reports the following: - AB 03:01 AM Support: RE: There is no eth0 device in 40-000065-4 release firmware
- Jeffrey,
Thank you. Yes, this instructions fixes the problem. Now my MityCam works well by eth0.
12/01/2016
- JM 07:56 AM Support: RE: There is no eth0 device in 40-000065-4 release firmware
- Anton,
I sent you an email with instructions on reconfiguring the camera. - Hello,
I've installed a 40-000065-4 release firmware from [[https://support.criticallink.com/redmine/projects/mityvision/wiki/MityCAM-B1910_Firmware]] (by the way, file name is MityCAM_B1910-40-000064-4_soc_camera.img.zip, not a MityC...
11/29/2016
- AB 07:40 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
- Thank you.
Yes, it's fully enclosed camera that was re-flashed several months ago in this post? [[https://support.criticallink.com/redmine/boards/21/topics/4794]]
Ok. I'll update a firmware. - JM 07:29 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
- Anton Bakulev wrote:
> I've tried to set clock rate to 40MHz but images acquired after that is zero valued. Did you tried this approach on your site?
The MityViewer uses this approach to adjust the clock when changing between rolling... - AB 05:42 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
- I've tried to set clock rate to 40MHz but images acquired after that is zero valued. Did you tried this approach on your site?
Also I've found that defailt clock rate is 283Mhz. Such a value was received after hard reboot of MityCam.
A...