Activity
From 10/23/2014 to 11/21/2014
11/21/2014
- KM 04:23 PM Support: RE: Pixel Clock B2521
- Yes I think it is time to upgrade the FG. Thanks for all the help.
Kyle - MW 04:20 PM Support: RE: Pixel Clock B2521
- Hi Kyle,
At the moment, the camera link serializer / pixel clock is fixed at 85 MHz. We would need to make you a custom FPGA image to drop the PLL rate down from 85 to 60. I need to see how complex that would be and get back to you.... - So I finally figure out the problem, my frame grabber can only handle a 60Mhz pixel clock. Is it possible to lower the pixel clock from 85 to 60?
Thanks,
Kyle - KM 03:44 PM Support: RE: B2521 Raw Order and Pixel Packing BASE mode
- Alrighty, thank you.
11/17/2014
- MW 04:00 PM Support: RE: B2521 Raw Order and Pixel Packing BASE mode
- Yes, currently base mode works the same in terms of readout order.
It would be possible to add a new mode in firmware to support psuedo single port readouts to support a standard raster order at the cost of reduced framerate (which fo... - Does BASE mode work similar to 10-Tap mode seen here:
https://support.criticallink.com/redmine/projects/mityvision/wiki/B2521_Raw_Order_and_Pixel_Packing
11/11/2014
- Thank you for visiting our MityCAM support forums.
Please feel free to post regarding any of our MityCAM products here. Please include the following so our engineering team, whom monitors these forums, can assist you quickly:
* Cam...