Activity
From 10/09/2022 to 11/07/2022
11/04/2022
- Hello,
Sperry would like to implement the PTP (Precision Time Protocol) protocol using the MitySOM-A10S module.
I have a couple of questions:
1. I believe we have to use the Intel Triple-Speed Ethernet FPGA IP core instead of the H...
11/03/2022
- TC 09:41 PM MitySOM-5CSX Altera Cyclone V PCB Development: RE: Switching MitySOM modules in DevKit
- Yes, the development kit is compatible with all modules in the 5CSX/5CSE family
- Because of availability we bough MitySOM dev kits that came with 5CSX-H6-42-RC MitySOMs. Can we use these with 5CSE-H4-3YA-RC modules?
10/31/2022
- DV 05:18 PM MitySOM-A10S Altera Arria 10 PCB Development: RE: KSZ9031 PHY replacements.
- Hi Costas,
Please take a look at the following wiki page that goes over alternates to the KSZ9031, it goes over the hardware and software impact of using either the KSZ9131 or KSZ9021 instead: https://support.criticallink.com/redmine/...
10/27/2022
- Hello,
The KSZ9031 Ethernet PHY is not available anymore or it has a long lead time.
We are using it with the MitySOM-A10S board.
Does Critical Link suggest any replacements for this PHY?
Thank you.