02/13/2012

MW 11:25 AM Support: RE: USB driver not responsive after camera is disconnected during acqusition
It's in the queue, but not being worked at this very moment. Haven't seen this behavior before here (and I'm sure we've unplugged the camera "hot"), so we'll need to first reproduce it.
-Mike
Michael Williamson
AC 10:57 AM Support: RE: USB driver not responsive after camera is disconnected during acqusition
Hi, just wondering if someone is taking a look into this issue? Anderson Chen

02/08/2012

AC 10:57 PM Support: RE: USB driver not responsive after camera is disconnected during acqusition
By disconnecting, I mean it is physically disconnected from the computer. The solution thus far has been to go into device manager, uninstall the driver, and re-plugging the device into the computer. Anderson Chen
OR 10:02 PM Support: USB driver not responsive after camera is disconnected during acqusition
Customer reports the following issue: If the MityCCD_I51100F is connected to the MityCCD Viewer and then it's disconnected in a middle of an acquisition, the driver becomes non-responsive and requires a driver reinstall from the device ... Omar Rahim
OR 09:58 PM Support: RE: Application does not receive callback from hardware trigger input
It's best to avoid making calls to camera DLL functions from within the callback routine. The best approach is to setting a flag in the callback routine which gets checked (and processed) in a different thread. Omar Rahim
 