Project

General

Profile

Activity

From 01/12/2025 to 02/10/2025

02/06/2025

DV 02:27 PM FPGA Development: RE: MitySOM-5csx custom board PL fabric ethernet access
Hi,
It looks like you have a signaltap in your design, which can make it hard to meet timing. I recommend that you remove it and try a build again. If that doesn't work then you'll need to use Timequest 's Worst Failing paths report t...
Daniel Vincelette
BK 02:14 PM FPGA Development: RE: MitySOM-5csx custom board PL fabric ethernet access
Hi,
I am facing an issue with new Timing Error in my Project which that generated rbf file, it was not pinging and as well as the source System continuously sending ARP messages only without sending the Ping data ,but in two systems E...
Bhardwaj Kotha

01/23/2025

TI 08:40 PM Software Development: RE: MTU increase Issue
What Dan showed you will start your application in the console... if your application exits (or you kill it with ctrl-c) you will be dropped to the command line, where you can restart your application or do other things. Tim Iskander
DV 06:55 PM Software Development: RE: MTU increase Issue
Hello,
As Tim said an application launched through cron won't have access to standard in and out. What you could do is have getty(the login manager) autologin as root and use a .profile config file to launch your application.
Here ...
Daniel Vincelette
BK 03:17 PM Software Development: RE: MTU increase Issue
Hi,
I am currently working with the MitySOM Cyclone V device, which has only a single UART port. During boot-up, the boot logs are coming through this UART port. Once the system finishes booting, it prompts for a login. I am manually ...
Bhardwaj Kotha

01/21/2025

TI 02:09 PM Software Development: RE: MTU increase Issue
If your program is reading from standard input, it will not be able to read anything when launched from cron. cron jobs have their standard input closed (or set to /dev/null, I don't remember exactly) and standard out will be shown in th... Tim Iskander
BK 01:03 PM Software Development: RE: Issue with crontab
Hi,
MTU size issue was Resolved, and now I am facing with Crontab.
Actually I am running an application code on boot time and that way I am added the Executable lines on crontab. I am facing an issue with that after booting, my code ...
Bhardwaj Kotha
MW 01:43 PM FPGA Development: RE: MitySOM-5csx custom board PL fabric ethernet access
The Quartus Platform designer adds logic between the AXI bridge (not sure which bridge you are using) and your Avalon Memory slave interfaces to account for the fact that the AXI interface is command / response vs. a more standard / typi... Michael Williamson
BK 01:18 PM FPGA Development: RE: MitySOM-5csx custom board Logic Utilization Issue
Hi,
I am working on Data transmission from HPS to FPGA fabric, So i am used Avalon Memory Interface in Platform Designer. The issue is when i am not using that Avalon Memory interface it takes 10974/15880(69%) Logic Utilization(in ALM...
Bhardwaj Kotha
 

Also available in: Atom