01/17/2019

VJ 09:32 AM Software Development: RE: Second PHY MDIO interface
Dan, thanks for your feedback. Lesson learned: Always rebuild the preloader.
That fixed my MDIO issue.
Regarding the PHY mode: I am using a 100Mb PHY with RMII interface, and I don’t think my original scheme with the Splitter and RGMI...
V J

01/14/2019

SA 05:55 PM Software Development: RE: RGMII pad skew on KSZ9031
Thanks for the reply Mike. I'll talk to the software team and see if VxWorks resets the PHY. If not, then we will try the script route. If it does, we'll talk more later.
Shane Avery
MW 11:22 AM Software Development: RE: RGMII pad skew on KSZ9031
Are you using uBoot to boot VxWorks?
I don't think there is enough space in the preloader to include the MDIO driver code and configure the RGMII, but I haven't ever tried that.
Updating the uBoot code should be pretty simple to ad...
Michael Williamson
DV 04:10 PM Software Development: RE: Second PHY MDIO interface
Hi Vidar,
It looks like you are using Critical Link's 4.9 branch, is that correct?
Have you rebuilt and updated your preloader since enabling EMAC0? Seeing as you saw TX data out of the MDIO interface I'm assuming you have but I'm ...
Daniel Vincelette
VJ 02:36 PM Software Development: Second PHY MDIO interface

Hi
I have added a second PHY to my board and connected it through the FPGA IO. I am using HPS EMAC0 and have added the emac splitter and the gmii_to_rgmii adapter in QSYS.
My problem is the MDIO interface. Connecting SignalTap to the...
V J

01/13/2019

SA 09:55 PM Software Development: RGMII pad skew on KSZ9031
We've got a custom board which is based on CriticalLink's baseboard. The PHY is the 9031. Try as we might to maintain the integrity of the RGMII signals on the PCB it seems the only way to get Gigabit working is to tweak the pad skew reg... Shane Avery
 